-10- Chapter Three: Setting and Unsetting Setting can be defined as activating the system. When the system is set, it monitors the zones that are prot

Strany 3 - Quick Reference Guide

-11- Setting with a Keyfob To set the system using a keyfob: • Press the relevant button on your keyfob (see 2.3: Keyfobs); the exit delay begins to

Strany 4 - Table of Contents

-12- 3.3: Set Status Indication The system’s set status is displayed on the front panel only. The following table explains the various set status desc

Strany 5

-13- Set Status Reply On receiving an Set Status request message, the system returns a status message to the sender. This message includes the system

Strany 6 - 1.5: Telecontrol

-14- Chapter Four: Panic Alarms Panic alarms enable you to send a message to the monitoring service in the event of an emergency. There are various ty

Strany 7 - 2.1: Front Panel Keypad

-15- Chapter Five: Home Automation and PGM Home Automation is an optional feature that requires an add-on expansion module. Home Automation enables yo

Strany 8 - 2.3: Keyfobs

-16- 5.4: SMS Control If your system supports cellular communication, you can control HA units and PGM remotely via your mobile phone using a number o

Strany 9 - 2.4: Wireless Keypad

-17- 3. From the HA unit’s sub-menu, select Off Time. 4. Enter a time (HH:MM). 5. Press √ when the desired setting is displayed. Weekly Schedule To

Strany 10 - 3.1: Setting the System

-18- Chapter Six: Telecontrol The infinite prime control panel offers a range of Telecontrol features that provide remote access via the telephone.

Strany 11 - 3.2: Unsetting the System

-19- The following commands are available: • Press “2” for Two-Way Audio. o If the TWA mode is defined as “Simplex” (see 6.5: Simplex Mode), the audi

Strany 12 - 7 ΤΟ ΕΞΙΤ

-2- infinite prime User Manual - Version 3.00 Catalog Number: 5IN1912 All data is subject to change w

Strany 13

-20- When the control panel calls, you will hear two short tones when you pick up the phone. Press "2" on your telephone to answer the call.

Strany 14 - Chapter Four: Panic Alarms

-21- Chapter Seven: Advanced System Operation Besides the basic functions described in the previous chapters, you can access additional functions via

Strany 15 - 5.2: Keyfob Control

-22- 7.2: Zone Bypassing/Unbypassing When a zone is bypassed, its sensor is ignored by the system and does not generate an alarm when triggered. To om

Strany 16 - 5.4: SMS Control

-23- Code 29: Telecontrol Code The Telecontrol code is designed to enable the user to perform a number of tasks via their telephone using DTMF command

Strany 17 - 4 Wednesday

-24- 7.4: Follow Me The Follow Me feature is designed to notify you when events have occurred within your security system. This notification may be an

Strany 18 - Chapter Six: Telecontrol

-25- 7.6: Service Menu The Service menu includes various functions that enable you to test your system effectively. You can gain access to the Service

Strany 19 - 6.4: Two-Way Audio Follow-Me

-26- Sounder Tests To test the external wireless sounder: • From the Service menu, select WL Sounder Test [703]; the wireless sounder is sounded brie

Strany 20 - 6.5: Simplex Mode

-27- The second utility, TX Test enables you to identify transmitters. In TX Test mode, each time a transmission is received, a chime is sounded and

Strany 21 - 7.1: Stop Communications

-28- Appendix A: Menu Structure Legend: Engineer code required Master code required

Strany 22 - 7.3: User Codes

-29- Appendix B: Glossary 24hr Zone A sensor which is always active regardless of whether the system is armed or unset. A Armed The state during

Strany 23

-3- Quick Reference Guide Function Press Additional Information SET If “One-Key Setting” is disabled enter your user code when setting. The d

Strany 24 - 7.5: Event Log

-30- G Global Chime A feature that enables/disables the Chime feature for the entire system – see Chime. H HA Units Home Automation Units (abbr.)

Strany 25 - 7.6: Service Menu

-31- S Scheduling A Home Automation feature that switches HA units on and off automatically according to pre-set times. Sensors The devices insta

Strany 26 - Σ=6 ΟΚ

-32- Electronics Line 3000 Ltd.: 14 Hahoma St. Rishon Le Zion 75655 Israel Tel:(+972-3)9637777 Fax:(+972-3)9616584 El

Strany 27

-4- Table of Contents Quick Reference Guide ...

Strany 28 - Appendix A: Menu Structure

-5- Chapter One: Introduction and Overview This user manual explains all you need to know about your infinite prime security system and provides step-

Strany 29 - Appendix B: Glossary

-6- 1.2: System Monitoring When an event occurs within the system, the control panel sends a message to your monitoring service describing the exact n

Strany 30

-7- Chapter Two: The User Interface There are several methods you can use to operate the system. Apart from the keypad on the front panel, your system

Strany 31

-8- Service Call Button The Service Call button enables you to contact the monitoring service and talk to an operator. Press and hold down the Servic

Strany 32 - Electronics Line 3000 Ltd.:

-9- 2.4: Wireless Keypad The system supports up to four wireless keypads. You can use the keypad as an setting station, perform basic home automation

Komentáře k této Příručce

Žádné komentáře