CHAPTER FOUR: PROGRAMMING
4.1: General
The Summit 3208GLD control panel can be programmed using either the 3108 LCD keypad or the Remote
Programmer, Electronics Line’s up/downloading software. For keypad operation refer to Chapter 3.
For programming using the Remote Programmer refer to the instructions provided with the software. Contact
your nearest Electronics Line office or agent to obtain a copy of the software.
4.2: Guide to Programming
The control panel has 500 parameter addresses. All the programmed data is stored in the EEPROM memory
and is saved even if both AC and battery power are disconnected. To make programming easier, the Summit
3208GLD includes a default program including typical values for most installations. This means that, in most
cases, only the programming of customer specific parameters (such as telephone numbers, account numbers,
etc.) is required. Programming changes are made by entering a new value at the appropriate address. This
chapter includes a complete list of parameter addresses and the options available for each address.
4.3: Programming Procedure
Electronics Line suggests the following:
Always load a default program when receiving a new panel by pressing SELECT 7, 2 (Default Program 1)
or SELECT 7, 3 (Default Program 2 - if available).
Before installation and programming, plan the application well using the programming form provided.
Use the following procedure to program the data from the programming form into the control panel.
To program the Summit 3208GLD using the 3108 LCD keypad:
1. Press SELECT 7, 1 to enter programming mode.
2. Enter an authorized user code.
3. Enter a 3-digit parameter address; the keypad displays the selected address within a group of related
parameters (zones, telephone numbers, routing etc.). For example, if a zone parameter address is
selected, the four parameters relating to that specific zone are displayed and the first digit of the selected
address flashes.
4. Pressing MENU/NEXT or entering data moves the cursor to the next parameter digit. To move back to the
previous digit press the Q.
5. To move to another item within the current group, press SELECT and then MENU/NEXT or Q to scroll
forwards and backwards through the available options. For example, if zone 1 is selected, the zone number
flashes when SELECT is pressed. MENU/NEXT and Q enable you to scroll forward and backwards through
the zones.
6. To exit programming mode, press AWAY.
7. For the modifications to take effect, disconnect and reconnect both AC and battery power supplies.
Note: The system allows two minutes to begin programming before automatically exiting programming
mode. Programming mode is immediately aborted if the control panel is in communication (both
incoming and outgoing calls).
LCD Keypad Programming Display
SELECT ADDR : 0 0 0
( 0 0 0 - 4 9 9 )
First digit blinking, any key will change this digit
Entering programming mode
Press:
Q
to move to the
previous digit
SELECT to select
another address or
group of parameters
MENU/NEXT to move
to the next digit or
group
AWAY to exit
programming mode